Instructions for use

MULTI-REG

B-FORM


Technical Information

MULTI-REG® is an occlusal registration and deprogramming device, developed by Prof. Stefano Pagano and Dr. Francesco Tortorella, useful in many dental fields whenever it is necessary to define, in a stable and reproducible manner, a defined occlusal registration.

Light-curing material, available in pre-formed plates and can be light-cured with all UV or halogen light devices. The pre-formed plates are supplied in a light-proof box, reusable as a container for transport or storage of models etc.

PRODUCT FOR PROFESSIONAL USE


Scope of application

  • Dental.
  • Multi-disciplinary (physiotherapy and/or osteopathy.

Dental: entire arch single layer (single thickness):

  • Recording in maximum intercuspation for verification, diagnosis-control in first visit.
  • Registration for requesting study models in various dental fields.
  • Post-preparation registration of crowns and bridges for inter-arch registrations.
  • Registration in the implant-prosthetic field, both in the diagnostic and prosthetic-rehabilitative phases.
  • Registration for bite prescriptions (Michigan simple type).
  • In the orthodontic field to verify or improve occlusal contacts using transparent alignment methods.

Dental: full arch multilayer (variable thickness):

  • Creation of temporary bite in a single session in acute temporomandibular disorders (emergency conditions, repositioning bite, joint chamber decompression (TMJ) and/or muscle deconditioning).
  • Recording during and/or after electromyographic/kinesiological investigation.
  • Registration before direct/indirect conservative treatment.

Dental: partial use (hemiarch, frontal group) single-multilayer:

  • On hemiarch during direct composite reconstructions.
  • In orthodontics to improve the occlusal alignment during the use of various treatment methods.
  • In the gnathological field, to be able to identify a mandibular posture and record this position.
  • Creating a temporary muscle deconditioning gig.

Multi-disciplinary (physiotherapy and/or osteopathy):

  • Possibility to check a mandibular posture and consequently be able to reset pre-existing muscular engrams.
  • Possibility to decompress the temporomandibular joint and manually analyze the tonic-fascial muscle changes.
  • Being able to use the material (therefore already deconditioning or temporary plates) in the tonic-postural field during the different cervical ROMs (accelerometer/Baiobit®), baropodometric platform according to the various procedures and protocols of use.
  • Possibility of use also in the kinesiological field, through the execution of various evaluation and/or diagnostic tests in the presence of occlusal adaptations recorded and maintained through the material.

TARGET PATIENT GROUP: Anyone who needs individual occlusal registrations and deprogramming for various types of dental treatments.

INTENDED USER: Dentist/Dentist, specialist in Gnathology and/or orthognathodontics. Physiotherapist, osteopath in agreement with the attending physician.


Preparation and use

  • Remove the pre-formed plate from the package and close it.
  • Apply the plate to the model (if already present) and define the contours of the arch and consequently of the future occlusal registration (optional phase).
  • In the absence of a model (e.g. during the first visit), apply an Optra-gate, adapt the plate to the patient's lower arch after having carefully eliminated excess saliva, adapt the material to the teeth with your fingers (preferably only on the occlusal area) trying not to press excessively.
  • Close the jaw, make the registration, and then proceed with polymerization, initially in the molar region and then incisal area. Complete the polymerization of the entire arch in the vestibular direction, then reopen the jaw, repeat opening/closing a couple of times and then polymerize the lingual sides. (Classic occlusal registration technique).
  • As regards multi-layer registration, it is advisable to carry out a classic registration, dry the obtained plate thoroughly and gradually apply further layers and polymerise each time (no adhesives of any kind will be necessary between the layers).

  • Polymerization times

    Polymerization with UV or halogen light, depending on the type of device.

    Finishing

    If necessary, finish the edges of the registration/plate obtained with a tungsten carbide cutter and smooth with sandpaper.

    Health

    Dip individual registration MULTI-REG® in a disinfectant solution based on glutaraldehyde. The duration varies according to the manufacturer's instructions.

WARNING: The product is designed for use in the dental field and must be used in accordance with the instructions for use. The manufacturer assumes no liability for damage resulting from any other use. Furthermore, the user is responsible for independently checking whether the material is suitable and usable in accordance with the intended purposes before use, especially if these are not stated in the instructions for use.


Thickness and format

This material is available in the following thickness and color:

HORSESHOE + RECTANGLE

#5002 - Thickness 2,3 mm - Color Blue - 20 pieces
UDI-DI = 8057509251152


Composition

Qualitative information

Urethane acrylate oligomer, vinyl ester resin, 2,2 dimethoxy-1,2-diphenylethane-1-one or 2,2 dimethoxy-2-phenylacetophenone,(+-)-2,3-dioxo-1,7,7-trimeyl-bicyclo-(2,2,1)-heptane di-ornane-2,3 dione, diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide, 2-hydroxy-2-methyl-1-phenyl-propan-1-one, 2-ethylhexyl-4-(dimethylamino)benzoate, 2,2 Diethoxyacetophenone, soda lime glass, amorphous silica, colorants (Pigment Blue CI 74160), flavors (Optamint).

Quantitative information

100 g contains 19 g of acrylates/methacrylates and 80 g of glass.


WARNING: The material contains methacrylates. Do not use in patients allergic to methacrylates or other substances contained in the product.


Symbology



Warnings

Effetti collaterali

There are no known unwanted side effects.

Interactions

There is no known interaction of the product with other medicines, drugs or other substances.

Food container

The product must be stored between 0°C and 22°C.

Minimum duration

Do not use MULTI-REG® beyond the expiration date.

Disposal

The uncured material can be polymerized with light (sunlight or artificial light) and then disposed of as plastic waste.


WARNING: In case of serious accident contact BART MEDICAL SRL - Telephone: +39 0544 523326 - E-mail: sales@bartmedical.com


FAQs

Find out more Read the product FAQs.

No, the layer MULTI-REG® and its support (pre-formed rectangle) do not require any preparation and are already set up for any type of recording and deprogramming.
No, the preformed layer MULTI-REG® once polymerized it is easily removed, the precautions will be to avoid excessive undercuts and therefore cause possible fractures.
It would be preferable to remove as much salivary content as possible and apply the layer MULTI-REG® on the lower arch to improve management.
Absolutely not, the physical-chemical characteristics of the material allow the flaps to be readjusted and registration to be carried out, which in turn can also be carried out in multiple parts (e.g. the incisor area and separately the premolar/molar area).
Of course, it is possible to make changes with a simple laboratory handpiece and related burs.
Absolutely not, you can handle the material calmly and carefully.
Like any plate and/or Bite, it will be necessary to sanitize it and store it carefully inside a container.
The registration MULTI-REG® single-layer or multi-layer can be sanitized like a normal silicone impression or recording, despite the rigidity of the material it is advisable to place it inside a transfer box/box.
The box containing the MULTI-REG® can be stored in a dry environment, free from humidity and light sources.
Of course, the layer MULTI-REG® or the support (rectangle) once polymerized and the optimal single/multilayer registration obtained will allow the clinician to detect the intermaxillary relationship using any commercial scanner and transfer all the digital data to the laboratory.

Manufacturer

BART MEDICAL

BART MEDICAL SRL
Viale Vincenzo Randi 118
48124 Ravenna (RA)
+39 0544 523326
sales@bartmedical.com
www.bartmedical.com


Support

For further information and technical support please contact us by email at sales@bartmedical.com